Shaanxi ASTTAR Explosion-proof Safety Technology Co., Ltd.

Based on the professional fields of explosion-proof and emergency response safety, take the "Safety", "Energy Saving" and "Environment friendly" as the theme to develop relevant industries.

Manufacturer from China
Active Member
9 Years
Home / Products / Instruments& Meters /

CD4 Portable explosion proof type Multi-parameter gas Detector

Contact Now
Shaanxi ASTTAR Explosion-proof Safety Technology Co., Ltd.
Contact Person:MrsShannon Tao
Contact Now

CD4 Portable explosion proof type Multi-parameter gas Detector

Ask Latest Price
Video Channel
Place of Origin :Shaanxi
Model Number :CD4
Delivery :China main port
MOQ :1PC
Packaging Details :Carton
Brand Name :ASTTAR
Certification :MA KA
Delivery Time :1-2 days for ready goods, 2-4 weeks for bulk order
Payment Terms :T/T, western union
Supply Ability :5000pcs/month
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Main features

1. Adopting thermal catalysis and electrochemical sensors, embedded microcontroller intellectual chip and electronic measuring device with LCD display screen, it can real-time detect the concentration of methane, oxygen, carbon monoxide and hydrogen sulfide in ambient air simultaneously.
2. With the function of date, time, temperature and humidity display, automatic backlight, intermittent sound and light alarm, adjustable alarm point and under voltage alarm.

Technical parameters

Main technical parameters
Gas Detected CH4 CO O2 H2S
Measurement range (0-4)% CH4 (0-1000) ×10-6 (0-25)% O2 (0-100) ×10-6
Intrinsic error 0-1 1-3 3-4 0-20 20-100 100-500 500-1000 0-5 5-25 0-49 50-100
±0.1 Ture value±10% ±0.3 ±2 ±4 Measurement value ±5% Measurement value ±6% ±0.5 ±3%FS ±3 Truth value ±10%
Resolution ratio 0.01 1.00 0.10 1.00
Sensor life >1yr (Thermocatalytic) >2 yr(Electrochemistry) >2 yr(Electrochemistry) >2 yr(Electrochemistry)
Response time ≤20s ≤45s ≤35s ≤45s
Sound intensity level >80dB
Battery pack 1800mAh( Ni-MH)

Operating

hours

>10h

Explosion proof type ExdibⅠMb
Dimensions (65× 125× 32)mm
Weight 0.5Kg
Operating environment

Temperature: 0℃ to 40℃; Relative humidity: ≤98%; Atmospheric pressure: 80kpa~116kpa.

Wind speed: ≤8 m/s; For the hazardous areas with explosive gas mixture.